Add to Cart
HCPL006 Diode Laser Power Supply 60A CW/60A QCW Testing Laser Power Supply
HCPL006 is a multi-functional power supply device that is carefully designed for optoelectronic device testing and burn-in scenarios. With CW and QCW two working modes, it can accurately output pulse and DC drive current, and it has CW and QCW output capabilities, CW and QCW currents can be up to 60A to meet diverse test needs. Its abundant detection and reserved interfaces can realize real-time monitoring and control of multiple parameters such as voltage, photocurrent, temperature, water flow, etc., and provide an efficient and reliable solution for complex test tasks with functions such as synchronous and parallel connection of multiple machines.
Product Features
▪ The CW and QCW operating modes can be switched freely, making it easy to cope with both stable and continuous current output (CW mode) and analog pulse conditions (QCW mode), greatly expanding the application scenarios
▪ The maximum measurement voltage is 60V, and it has the characteristics of self-adaptation with the load, and the output can be automatically adjusted according to the connected load to ensure the stable operation of the equipment under various working conditions.
▪ Support custom sequence output, users can flexibly set the output sequence according to specific test needs; The multi-machine synchronous and parallel function can meet the needs of large-scale and high-power test tasks, improving test efficiency and system scalability
▪ The water cooling and heat dissipation method is used to effectively reduce the temperature of the equipment during operation, ensure long-term stable work, and prolong the service life of the equipment
Product Parameters
Items | Parameters |
Power input |
220V, 50/60Hz |
Working modes |
CW and QCW |
Pulse width |
100μs min., 1μs steps |
Pulse Frequency |
Maximum duty cycle 100% @60A, 10kHz, 0.1Hz steps |
Pulse drive current |
60A in 15mA steps |
DC drive current |
60A, 15mA steps |
Drive current accuracy |
±0.1%±30mA@20A range; ±0.1% ±100mA@60A range |
Output voltage |
60V, adaptive with load |
Voltage measurement |
range 3V, accuracy ±0.1%±2mV; The range is 30V, and the accuracy ±0.1%±10mV; The range is 60V, and the accuracy ± 0.1%±80mV |
Number of voltage measurement channels |
16 channels for time-sharing multiplexing |
Photocurrent detection |
0.1mA range, accuracy ±0.5%±1μA; 1mA range, ±0.5%±8μA; 10mA range, ±0.5%±60μA |
Number of optical flow detection channels |
16 channels for time-sharing multiplexing |
Number of temperature monitoring channels |
32 channels for time-sharing multiplexing |
Number of channels for water flow monitoring |
8 |
Power supply size |
19" 4U, depth 480mm |
Heat dissipation method |
water cooling |
Applications
▪ Scientific research experiments and teaching: provide professional testing equipment for experimental teaching and scientific research projects in optics, electronics and other related disciplines in universities and scientific research institutions, help researchers deeply explore the physical properties and working principles of optoelectronic devices, and promote the output of scientific research results
▪ Industrial automation testing: integrated into the industrial automation production line, the optoelectronic devices are quickly and massively detected online, product defects are found in time, production efficiency and product yield are improved, and the stability and reliability of the production process are guaranteed